POWER ENTRANCE MODULE
The power entrance module contains the power off/on switch, fuse holder, voltage selector and power cord receptacle.
To open the power entrance module to replace the fuse or change voltage use a small screwdriver, ball point pen or similar device. Remove the power cord, insert tip of tool at a 45 degree angle into notch between the power cord receptacle and power module cover, apply pressure towards cover while prying upward.
To change the fuse, the fuse holder is attached to the cover and the fuse is easily removed and replaced. If the fuse again blows almost immediately, unplug the amplifier and do not attempt to use it until the cause of the problem has been determined. Refer to the trouble shooting section of this manual.
To change from 120 to 240 volts pull the voltage selector card straight out of the housing using the indicator pin. Orient the selector card so that the desired voltage is readable at the bottom of the card. Orient indicator pin to point up when desired voltage is readable at the bottom. Insert voltage selector card into the housing with edge showing selected voltage entering first and printed side of card facing the fuse compartment. Reinstall cover and verify the indicator pin shows the desired voltage.
If required the fused holder may be changed to take European standard fuses. Remove the Phillips head screw holding the fuse holder to the cover, turn the holder over and reinstall with the screw. The European arrangement requires two fuses..