INSTRUCTIONS FOR CHANGING TONE ARM ON MICRO-75A SOUND SYSTEM


Stand the unit up (carrying position) and locate the chrome handle cover. Slide a screwdriver under one end of the handle cover and it will pop off. Remove the two bolts holding the handle in place. On the opposite side are two rubber feet. Take the bolt out of each of the rubber feet. The whole unit will slide out of the case.


Lift the turntable out of the spindle and set it aside. Refer to the diagram below and remove the three bolts as indicated. The power supply will drop down, allowing you to get to the tone arm. Unsolder the two wires and remove the hex nut from the tone arm and remove the arm assembly. Re-install the new arm and re-assemble the unit.